Computer Performance, Logon Scripts

Code Error 800A01C3 - Object not a collection

Troubleshooting Code 800A01C3 - Object not a collection

Introduction to Code 800A01C3

Error code, 800A01C3 occurs when you execute a WMI / VBScript.  This is a runtime error check the names of your objects. Go through the spelling of the object names with a fine toothcomb.

The Symptoms you get Code 800A01C3 - Object not a collection

The script does not execute as you hoped, instead you get a WSH error message.

The Cause of Code 800A01C3

Your VBScript has a misspelled WMI object.   Note: The clue Source: Microsoft VBScript runtime error. The actual error message is a little obscure, however it is alerting you the fact that WSH does not know a WMI object, which you have attempted to use.

Incidentally, Source: reports a runtime error not a compilation error, this means you are looking not for a pure syntax problem, but a fault logic error.  In the case of runtime errors, you can use this temporary work around.  Add this statement just before the line which errors: On Error Resume Next.

N.B. Jim C. reports it maybe a firewall setting on the client which prevents the script from running successfully.

The Solutions

Check the names in your script, pay particular attention to WMI objects.  Note: The Line: 4 Char: 1  In this case it is not Char 1 to blame, more that there is something wrong and none of the line can execute.

As a last resort, in the case of runtime errors, you can add this line:
On Error Resume Next.

Example1 of Error 800A01C3 Script

Note: The Line: 4 objWMIService

It should be objWMISystem

 

strComputer = "Alan"
set objWMIService = GetObject("Winmgmts:\\" & strComputer)
set colOperatingSystems = objWMIService.InstancesOf("win32_OperatingSystem")
For each objOperatingService In colOperatingSystems
WScript.echo "Name " & objOperatingSystem.name & vbCRLf & _
"Caption " & objOperatingSystem.caption & vbcrlf & _
"Time Zone " & objOperatingSystem.currentTimeZone & vbcrlf & _
"OS Type " & objOperatingSystem.OsType
Next

 

 

Example 2 Exchange User

Randy C wrote in saying that he had the same 800A01C3 error with Exchange proxyAddresses.

 

.....

for each email in oUser.proxyAddresses

     OutPutFile.Write email & ","

Next

 

 

Solarwinds IpMonitorTry a different solution, download SolarWinds ipMonitor

Here is my thinking, ipMonitor will give you valuable data about your network and servers.  This extra information just may unlock the solution to your error code.  One more thing, sometimes when troubleshooting you go around in circles; therefore if you try a different, but related approach, you may just crack the problem.  Free Download of SolarWinds ipMonitor

Computer Training Software - Recommended Training VideosGuy Thomas recommends Computer Training Software

Their topics and material are ideal for getting you started with VBScript.  The videos are easy to follow and you can control the pace.  Try their free demo material and then see if you want to buy the full package. See more about VB Script Training CD.


Do you need extra help?

For interpreting the WSH messages check Diagnose 800 errors.

For general advice try my 7 Troubleshooting techniques

Give something back?

Would you like to help others?  If you have a good example of this error, then please email me, I will publish it with a credit to you:

 

 *